Retinal vascular segmentation using superpixel-based line operator and its application to vascular topology estimation

1月 1, 2018·
Tong Na
,
Jianyang Xie
,
Yitian Zhao
Yifan Zhao
Yifan Zhao
,
Yue Liu
,
Yongtian Wang
,
Jiang Liu
· 0 分钟阅读时长
DOI
摘要
PURPOSE: Automatic methods of analyzing of retinal vascular networks, such as retinal blood vessel detection, vascular network topology estimation, and arteries/veins classification are of great assistance to the ophthalmologist in terms of diagnosis and treatment of a wide spectrum of diseases. METHODS: We propose a new framework for precisely segmenting retinal vasculatures, constructing retinal vascular network topology, and separating the arteries and veins. A nonlocal total variation inspired Retinex model is employed to remove the image intensity inhomogeneities and relatively poor contrast. For better generalizability and segmentation performance, a superpixel-based line operator is proposed as to distinguish between lines and the edges, thus allowing more tolerance in the position of the respective contours. The concept of dominant sets clustering is adopted to estimate retinal vessel topology and classify the vessel network into arteries and veins. RESULTS: The proposed segmentation method yields competitive results on three public data sets (STARE, DRIVE, and IOSTAR), and it has superior performance when compared with unsupervised segmentation methods, with accuracy of 0.954, 0.957, and 0.964, respectively. The topology estimation approach has been applied to five public databases (DRIVE,STARE, INSPIRE, IOSTAR, and VICAVR) and achieved high accuracy of 0.830, 0.910, 0.915, 0.928, and 0.889, respectively. The accuracies of arteries/veins classification based on the estimated vascular topology on three public databases (INSPIRE, DRIVE and VICAVR) are 0.90.9, 0.910, and 0.907, respectively. CONCLUSIONS: The experimental results show that the proposed framework has effectively addressed crossover problem, a bottleneck issue in segmentation and vascular topology reconstruction. The vascular topology information significantly improves the accuracy on arteries/veins classification.
类型
出版物
Medical Physics, 45(7), 3132–3146. American Association of Physicists in Medicine: Medical Physics
publications
赵一帆
作者
赵一帆 (he/him)
讲席教授
赵一帆(Yifan Zhao), 宁波东方理工大学力学与机械工程学院讲席教授, 英国皇家工程院工业会士, 英国高等教育学会会士, 2025入选国家级高层次人才计划。曾任英国克兰菲尔德大学航空、交通与制造学院终身教授、博士生导师, 担任全生命周期工程服务实验室主任。2000年与2003年分别获得北京理工大学自动控制专业学士和硕士学位, 2007年获得英国谢菲尔德大学自动控制与系统工程博士学位。累计发表高水平学术论文200余篇, 其中包含IEEE Transactions顶刊论文30余篇, 以及CVPR、MICCAI、CIRP等国际顶级会议论文。出版学术专著6部, 获授权国际专利3项。已培养博士后6人、博士研究生20余人、硕士研究生80余人, 国际访问学者10名。主持和参与多项英国工程与自然科学研究理事会、英国皇家工程院、英国创新署以及空客和捷豹路虎等国际头部企业资助的重大科研项目, 累计经费逾8000万元人民币。在知识转化方面, 其研究成果已成功应用于飞机设计与运维、智能制造、自动驾驶以及智慧建造等领域。